PEAT International Commissions Plasma Thermal Waste to Energy System in China

Medical Waste Treatment, PTDR Systems, Plasma Arcs, Plasma Gasification, TVRC Technology, Waste To Energy, Waste To Resources, Waste Treatment No Comments »

Northbrook, Illinois & Shanghai, China – October 10, 2013 – PEAT International, Inc., (“PEAT”) a leader in plasma-thermal waste destruction systems, announced the successful commissioning of a Plasma Thermal Destruction and Recovery (“PTDR”) system in Shanghai, China. The 60 kg/hr system – designed for medical waste and oil refinery sludge – was installed for Abada Plasma Technology Holdings, Ltd. – an Asian-based renewable energy project developer.

PEAT’s PTDR “single stage” plasma-thermal process transforms hazardous waste through molecular dissociation at 1,500°C (2,732°F) into recoverable, non-toxic end-products, synthetic gas and heat (sources for energy recovery), metals and a vitrified glass matrix. Emissions are below the most stringent environmental standards used anywhere.

“This is end-stage technology and sets the standard for clean hazardous waste remediation. Only with plasma can you achieve temperatures high enough for waste destruction in a single-staged process,” said Joseph Rosin, PEAT International Chairman. “It’s a 21st century solution that addresses three important needs: significant volume reduction, full pollution control and competitive pricing. We are currently preparing for other projects already under contract.”

PTDR systems are in operation in California, Taiwan and China. Go to http://www.peat.com/chinasystem.html for a video of operations and acceptance test run data.

About PEAT International

PEAT International, Inc., headquartered in Northbrook, Illinois, with offices in China, Taiwan and India, is a waste-to-energy (“WTE”) company with its two proprietary technologies – the Plasma Thermal Destruction and Recovery™ (“PTDR”) technology for the treatment and recycling of industrial, medical and other hazardous waste streams and the Thermal Volume Reduction & Conversion™ (“TVRC”) technology for municipal solid waste. For more information, contact Daniel Ripes, dripes@peat.com, at 847-559-8567 and visit www.peat.com.

Plasma-Arc Gasification And Emissions

Emissions, Medical Waste Treatment, PTDR Systems, Plasma Arcs, Plasma Gasification, Waste To Energy, Waste To Resources, Waste Treatment 1 Comment »

Previously, we discussed and demonstrated how plasma arc plasma gasification nearly eliminates dioxin formation, this entry looks to address semi-volatile heavy metal compounds and other air emissions.

The high temperatures at which the plasma-arc plasma gasification processes operate can result in the generation of volatile inorganic constituents (i.e. metals and metal oxides), sometimes at a higher level than compared to convention thermal treatment processes, particularly if the waste feedstock comes in direct contact with the very hot plasma-arc plasma gasification plume as these compounds may become volatilize and carried downstream with the syngas generated. While many are removed by the gas cleaning and conditioning systems, in plasma-arc plasma gasification processes where the off gases are not cooled (i.e. plasma combustion, which is not utilized by PEAT) these heavy metal compounds could be carried out in the stack gases, increasing the levels of potential contaminants that are emitted.

Downstream of any quench system or syngas cooler, any entrained particulate matter and/or acid gases (H2S, HCl, etc.) are scrubbed with water typically using either a packed-bed tower/Venturi scrubber or through a dry filtration system. Additional equipment in the form of HEPA or baghouse filters may also be utilized.

The results presented in the below reflect emissions from PEAT International plasma-arc plasma gasification waste-to-energy systems where the syngas was not utilized and ultimately processed in a thermal oxidizer or secondary reaction chamber.

Emission /
Waste Stream

Sulpho-phenyl
methyl pyrazolone,
(High Sulfur (20%),
High Chlorine (14%))
Gujarat, India

Incinerator fly ash
and medical waste
in Tainan, Taiwan

Medical Waste
in Gujarat, India

PM (gr/scf) 0.00817 0.004806 0.01057
CO (ppmv)

ND
(DL: 0.08 ppm)

ND
(DL: 2.8 ppm)

NR

NOx (mg/nm3)

0.35

48.95

129.32

SOx (mg/nm3)

13.1

55.03

22.72

HCl

ND
(DL: 0.00671 ppm)

ND
(DL 5.1 ppm)

ND
(DL 1 ppm)

Lead (μg/nm3)

NR

43.46

ND
(DL 1.0 μg/m3)

Cadmium

NR

1.94 μg/nm3

19.51 μg/m3

Mercury

NR

6.4 μg/nm3

ND
(D.L. 1.0 μg/m3)

VOCs

NR

NR

ND
(D.L. 1mg/m3)

APC system for each system only included wet venturi scrubber and baghouse filter

New Environmental Data from system in Shanghai

Medical Waste Treatment, PTDR Systems, Plasma Arcs, Plasma Gasification, Waste To Energy, Waste To Resources, medical waste No Comments »

As discussed earlier in this blog, a vitrified matrix or slag is the primary solid byproduct of plasma arc waste-to-energy processing. The vitrified matrix from plasma arc processing contains the mineral matter associated with the feed materials in a vitrified form – a hard, glassy-like substance. The amount of matrix produced is a function of how much non-combustible mineral matter is present in the feedstock.

This matrix is the result of operating temperatures within the plasma arc reactor above the melting temperature of the mineral matter. Under these conditions in the plasma arc reactor, non-volatile metals and metal oxides bind together in molten form until it is cooled via natural heat loss or via a pool of water, where it would fracture and granulate.

The compressive strength of a slag sample generated from fly ash from coal-fired power plant as well as some sodium carbonate (fluxing agent) was 480 kg/cm2, while its average mortar strength was tested at 169 kg/cm.

The vitrified matrix or slag generated by plasma arc treatment is primarily made up of silicon dioxide (SiO2), aluminum oxide (Al2O3) and calcium oxide (CaO). Toxicity Characteristic Leaching Procedure (TCLP) tests are designed to determine the mobility of both organic and inorganic analytes present in the slag. The most recent TCLP results conducted in March 2013 on the vitrified matrix from the plasma arc waste-to-energy system located in Shanghai is presented in the below table along with previous results from processing refinery sludge.

Also, here are recent pictures of this system.

http://www.peat.com/ptdr_pictures.html

Contaminant USA – EPA
(40 CFR 261.24)
Regulatory Level
(mg/L)
China EPA
Regulatory Level
(mg/L)

China Medical Waste
Vitrified Matrix
(mg/L)

China Refinery
Vitrified Matrix
(mg/L)

Arsenic

5 5 ND <0.026 ND < 0.050

Barium

100 100 0.797 0.371

Cadmium

1

1 ND < 0.007 ND < 0.008

Chromium

5 5 0.173 ND < 0.017

Copper

15 < 0.100 (0.015) 8.7

Hexavalent Chromium

2.5 ND < 0.01 ND < 0.25

Lead

5 5 ND 0.014 ND < 0.018

Mercury

0.2 0.2 ND < 0.0005 ND < 0.0005

Nickel

0.121 0.441

Selenium

1 1 ND < 0.024 ND < 0.041

Silver

5 5 ND < 0.006 ND < 0.013

Zinc

0.378 1.22

ND = Not Detectable (detectable limit follows)

Medical Waste Treatment

Medical Waste Treatment, PTDR Systems, Plasma Arcs, Plasma Gasification, Waste To Energy, Waste Treatment, medical waste 4 Comments »

Medical and pharmaceutical waste comes from hospitals, doctors/dentists offices, skilled & unskilled nursing care, group practices, specialized out-patient services and veterinarians. Examples of medical waste are: soiled or blood soaked bandages, culture dishes and other glassware, discarded surgical gloves, and instruments (e.g. scalpels), needles, cultures, stocks, swabs used to inoculate cultures, removed body organs and lancets used to draw blood samples.

For medical waste generators (medium and large hospitals/health clinics or medical waste collectors), the current trend is clearly in the direction of greater efficiency in sorting. The pressure for cost containment has grown in the health care industry and the price for medical waste treatment and disposal has increased. It has been estimated that hospitals and long-term care (LTC) facilities in the US waste generate at least 125 million pounds of pharmaceuticals annually. Our research reflects that medical waste treatment systems are expected to experience high growth due to a growing and aging population, a rising incidence of chronic disease, and new requirements for disposal in community and home settings.

PEAT’s PTDR plasma-arc plasma gasification system in Sacramento, CA is currently permitted for sanitized medical waste treatment, among other waste streams. The PTDR plasma-arc plasma gasification technology has received numerous regulatory approvals throughout the globe, including the California Department of Public Health, which certified the technology as an alternative to incineration for medical waste treatment.

Since October 2011, PEAT has been performing small medical waste treatment campaigns. Most recently in August, PEAT hosted potential clients from Utah to witness a medical waste treatment campaign on waste supplied from the San Jose area.

Medical Waste Treatment

Waste Treatment 1 Comment »

The EPA first issued new performance standards for medical waste incineration in 1986 and then again in 1997 to curb pollutants, which prompted many hospitals to shut down their incinerators. Hospitals turned to autoclaving and steam sterilization, which can only treat limited aspects of medical waste and do not provide any volume reductions.

Over 2,300 medical waste incinerators have closed since 1997 and currently 57 (31 are operated by hospitals) are still online. EPA officials estimate that the new rules passed recently will cost roughly $15.5 million. If that was divided evenly over the 57 locations, that’s over $270,000 per location.

Reducing medical waste incineration is just one side; waste still needs to be thermally treated. At least 14 states have statues requiring incineration of trace-chemotherapy agents and pathological waste – both waste streams can be treated by Plasma Thermal Destruction and Recovery (PTDR).

 